|
Abstracts from U.Va on Hyperpolarized
Noble Gas MR:
10th Annual Scientific
Meeting of the International Society of Magnetic Resonance
in Medicine (I.S.M.R.M.), Hawaii, May 2002
Hyperpolarized Gas MRI Helium-3:
1. Mugler J, Salerno M, de Lange E, Brookeman J. Optimized
TrueFISP Hyperpolarized 3He MRI of the Lung Yields a 3-fold
SNR Increase Compared to FLASH. Poster.
2. Mugler J, Salerno M, Brookeman J. Reducing
Diffusion-Induced Signal Loss in Hyperpolarized 3He MRI.
Poster
3. Salerno M, Altes A, Brookeman J, de Lange
E, Mugler J. Validation
of Interleaved-Spiral Hyperpolarized 3He Diffusion MRI. Poster
4. Salerno M, Brookeman J, de Lange E, Mugler
J. Hyperpolarized 3He
Spiral Lung Imaging at High and Low Field Strengths (1.5T
and 0.45T): A Study of Susceptibility and off-Resonance Effects.
Poster
5. Cooley B, Acton S, Salerno M, Ray N, Tustison
N, de Lange E, J Brookeman, Altes T. Automated
Scoring of Hyperpolarized Helium-3 MR Lung Ventilation Images:
Initial Development and Validation. Poster
6. Salerno M, Mugler J, Cooley B, Brookeman
J, de Lange E, Altes T. Hyperpolarized
3He Diffusion Imaging in Smokers: Comparison with Computed
Tomography and Spirometry.
Oral presentation:
7. De Lange E, Altes A, Jones D, Daniel M, Salerno
M, Brookeman J, Mugler J. Bronchiolitis
Obliterans following Lung Transplantion: Evaluation with Hyperpolarized
Helium-3 MR Imaging. Poster
8. Mata J, Altes T, Christopher J, Mugler J,
Brookeman J, de Lange E. Transient,
Position-Dependent Ventilation Defects of the Lung in Healthy
Volunteers: Demonstration with Hyperpolarized Helium-3 MR
Imaging. Poster
9. Mata J, Christopher J, de Lange E, Mugler
J, Brookeman J. MRI of the
Human Lungs with Hyperpolarized Helium-3: Considerations of
Appropriate Dose. Poster
10. Puderbach M, Salerno M, de Lange E, Weiler
N, Schreiber W, Thelen M, Kauczor H-U. He3-MRI
measurement of ventilated lung volumes in volunteers and patients
at two institutions-Comparison with pulmonary function tests.
(joint submission with Univ of Mainz) Poster.
11. Keilholz S, Altes A, Knight-Scott J, Christopher
J, Berr S, de Lange E. Comprehensive
Pulmonary MR Imaging Using Hyperpolarized 3He, O2 and Gadolinium.
Oral presentation: Friday, May 24 2002 12:18PM Room 313A
Hyperpolarized Gas MRI Xenon-129:
1. Ruppert K, Mata, J Brookeman J, Hagspiel K, Mugler J. Detecting
Lung Tissue Density Variations with XTC MRI. Poster
2. Ruppert K, Mata, J, Brookeman J, Hagspiel
K, Mugler J. Xenon Uptake
and Exchange Dynamics in the Rabbit Lung. (3 joint submissions
with Advanced MRI Technologies). Poster.
|